<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>FOSS &#8211; Vinca Labtech</title>
	<atom:link href="https://www.vincalabtech.com/brand/foss/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.vincalabtech.com</link>
	<description></description>
	<lastBuildDate>Wed, 20 May 2026 10:00:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.1</generator>

<image>
	<url>https://www.vincalabtech.com/wp-content/uploads/2026/03/cropped-vinca-logo-set-0155-50x50.jpg</url>
	<title>FOSS &#8211; Vinca Labtech</title>
	<link>https://www.vincalabtech.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>NIRS DS3 Feed Analyser</title>
		<link>https://www.vincalabtech.com/product/nirs-ds3-feed-analyser/</link>
					<comments>https://www.vincalabtech.com/product/nirs-ds3-feed-analyser/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 10:30:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3180</guid>

					<description><![CDATA[<p class="sub-header">Advanced feed analysis for everyone. The innovative NIRS™ DS3 combines unique analytical performance with the latest software and networking services, making reliable test data for decision-making more available than ever. It’s a complete solution that supports all aspects of your analytical operations from calibration development to measurement and data integration.</p>]]></description>
										<content:encoded><![CDATA[<h3>Technical Specification</h3>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Dimensions (w x d x h)</td>
<td>375 x 490 x 300 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>27 kg</td>
</tr>
<tr>
<td>Degree of protection</td>
<td>IP 65</td>
</tr>
<tr>
<td>Measurement mode</td>
<td>Reflectance or transflectance (for liquids)</td>
</tr>
<tr>
<td>Wavelength range</td>
<td>400 &#8211; 2500 nm</td>
</tr>
<tr>
<td>Detector</td>
<td>Silicon (400 &#8211; 1100 nm), Lead Sulphide, PbS (1100 &#8211; 2500 nm)</td>
</tr>
<tr>
<td>Optical bandwidth</td>
<td>8.75 ± 0.1 nm</td>
</tr>
<tr>
<td>Data resolution</td>
<td>0.5 nm</td>
</tr>
<tr>
<td>Number of data points</td>
<td>4200</td>
</tr>
<tr>
<td>Number of subsamples</td>
<td>Default: 7 for small cup; 8 for large cup</td>
</tr>
<tr>
<td>Self test</td>
<td>12 minutes (variable)</td>
</tr>
<tr>
<td>Analysis time</td>
<td>&lt;1 minute for 32 scans (8 subsamples, 4 scans per subsample)</td>
</tr>
<tr>
<td>Network connections</td>
<td>IQX<img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Device Management</td>
</tr>
<tr>
<td>Installation requirements</td>
<td></td>
</tr>
<tr>
<td>Voltage supply</td>
<td>100-240 V AC*, frequency 50-60 Hz, Class 1, protective earth</td>
</tr>
<tr>
<td>Ambient temperature</td>
<td>5 &#8211; 40°C</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>-20 to 70°C</td>
</tr>
<tr>
<td>Ambient humidity</td>
<td>&lt; 93% RH</td>
</tr>
<tr>
<td>Mechanical environment</td>
<td>Stationary during use</td>
</tr>
<tr>
<td>EMC environment</td>
<td>Laboratory use, industry requirements</td>
</tr>
<tr>
<td>*Mains supply voltage fluctuations not exceeding ±10% of the rated voltage.</td>
<td></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/nirs-ds3-feed-analyser/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Infratech Whole Grain &#038; Flour Analyser</title>
		<link>https://www.vincalabtech.com/product/infratech-whole-grain-flour-analyser/</link>
					<comments>https://www.vincalabtech.com/product/infratech-whole-grain-flour-analyser/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 10:30:20 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3179</guid>

					<description><![CDATA[<p class="sub-header">Solid, straightforward and reliable, Infratec™ draws on the latest advances in NIR technology, connectivity and usability. It makes the job of quality control easier and less time-consuming as a reliable cornerstone for any grain handling operation.</p>]]></description>
										<content:encoded><![CDATA[<h2 class=" blue" style="text-align: center;">Technical specification</h2>
<div class="table__shadow">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td align="left" valign="top"><strong>Feature</strong></td>
<td colspan="2" align="left" valign="top"><strong>Specification</strong></td>
</tr>
<tr>
<td align="left" valign="top">Dimensions (W x D x H)</td>
<td colspan="2" align="left" valign="top">410 x 460 x 415 mm</td>
</tr>
<tr>
<td align="left" valign="top">Weight</td>
<td colspan="2" align="left" valign="top">28.5 kg (31 kg with test weight module)</td>
</tr>
<tr>
<td align="left" valign="top">Voltage</td>
<td colspan="2" align="left" valign="top">220-240V 50-60Hz or 110-120V</td>
</tr>
<tr>
<td align="left" valign="top">Rated current</td>
<td colspan="2" align="left" valign="top">1.0A (110-120V) / 0.5A (220-240V)</td>
</tr>
<tr>
<td align="left" valign="top">Fuse</td>
<td colspan="2" align="left" valign="top">T 5 A (250V)</td>
</tr>
<tr>
<td align="left" valign="top">Power consumption</td>
<td colspan="2" align="left" valign="top">85 W (24V)</td>
</tr>
<tr>
<td align="left" valign="top">Input supply</td>
<td colspan="2" align="left" valign="top">24V DC from FOSS approved power supply</td>
</tr>
<tr>
<td align="left" valign="top">Spectrometer</td>
<td colspan="2" align="left" valign="top">Scanning monochromator</td>
</tr>
<tr>
<td align="left" valign="top">Wavelength range</td>
<td colspan="2" align="left" valign="top">570 &#8211; 1100 nm</td>
</tr>
<tr>
<td align="left" valign="top">Detector</td>
<td colspan="2" align="left" valign="top">Silicon</td>
</tr>
<tr>
<td align="left" valign="top">Optimal bandwidth</td>
<td colspan="2" align="left" valign="top">7 nm</td>
</tr>
<tr>
<td align="left" valign="top">Number of data points/scan</td>
<td colspan="2" align="left" valign="top">1061</td>
</tr>
<tr>
<td align="left" valign="top">Mode</td>
<td colspan="2" align="left" valign="top">Transmittance</td>
</tr>
<tr>
<td align="left" valign="top">Light source</td>
<td colspan="2" align="left" valign="top">Tungsten halogen lamp</td>
</tr>
<tr>
<td align="left" valign="top">Interface</td>
<td colspan="2" align="left" valign="top">Ethernet, 3 x USB (full function) including one on the instrument front for easy access</td>
</tr>
<tr>
<td align="left" valign="top">Display</td>
<td colspan="2" align="left" valign="top">10 inch capacitive touch screen</td>
</tr>
<tr>
<td align="left" valign="top">Noise Level</td>
<td colspan="2" align="left" valign="top">&lt; 70 dB(A)</td>
</tr>
<tr>
<td align="left" valign="top">Degree of protection</td>
<td colspan="2" align="left" valign="top">IP 54</td>
</tr>
<tr>
<td align="left" valign="top"></td>
<td colspan="2" align="left" valign="top"></td>
</tr>
<tr>
<td colspan="3" align="left" valign="top"><strong>Sample handling and result presentation</strong></td>
</tr>
<tr>
<td align="left" valign="top">Analysis time</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Less than 60 seconds for 10 sub-samples including test weight analysis and as little as 40 seconds when dynamic sub-sampling enabled</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Path length</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Variable cell automatically controlled from 6 &#8211; 33 mm</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Result report</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Presented on the display as default. Can be sent to PC/LIMS and the printer port</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Outlier function</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Warnings and options for the presentation of the result</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Software</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Menu driven with touch screen interface</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Regression programs</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">ANN (Artificial Neural Network); PLS (Partial Least Squares)</p>
</td>
</tr>
<tr>
<td align="left" valign="top">No. of sub-samples</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Between 1 and 30 sub-samples (10 sub-samples standard)</p>
</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/infratech-whole-grain-flour-analyser/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>NIRS™ DA1650 Oilseed Crush Analyser</title>
		<link>https://www.vincalabtech.com/product/nirs-da1650-oilseed-crush-analyser/</link>
					<comments>https://www.vincalabtech.com/product/nirs-da1650-oilseed-crush-analyser/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 10:29:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3175</guid>

					<description><![CDATA[<strong>Key features of the NIRS™ DA1650 for Oilseed Crush analyser
</strong>
•<span class="Apple-tab-span"> </span>ISO compliant NIR analysis
•<span class="Apple-tab-span"> </span>Rapid analysis of protein, moisture and oil
•<span class="Apple-tab-span"> </span>Low maintenance
•<span class="Apple-tab-span"> </span>Robust design
•<span class="Apple-tab-span"> </span>Factory standardised
•<span class="Apple-tab-span"> </span>Compatible with other FOSS NIR solutions
•<span class="Apple-tab-span"> </span>Ready to use calibrations for a variety of sample types
•<span class="Apple-tab-span"> </span>Remotely supported through Mosaic network software
•<span class="Apple-tab-span"> </span>Built-in computer with intuitive touchscreen interface]]></description>
										<content:encoded><![CDATA[<h3>Technical Specification</h3>
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td align="left" valign="top"><strong>Feature</strong></td>
<td align="left" valign="top"><strong>Specification</strong></td>
</tr>
<tr>
<td align="left" valign="top">Dimensions (W x D x H)</td>
<td align="left" valign="top">230 x 530 x 280 mm</td>
</tr>
<tr>
<td align="left" valign="top">Weight</td>
<td align="left" valign="top">16 kg</td>
</tr>
<tr>
<td align="left" valign="top">Degree of protection</td>
<td align="left" valign="top">IP 65 (Dust and water proof)</td>
</tr>
<tr>
<td align="left" valign="top">Measurement mode</td>
<td align="left" valign="top">Reflectance</td>
</tr>
<tr>
<td align="left" valign="top">Wavelength range</td>
<td align="left" valign="top">1100 – 1650 nm</td>
</tr>
<tr>
<td align="left" valign="top">Detector</td>
<td align="left" valign="top">Diode array</td>
</tr>
<tr>
<td align="left" valign="top">Analysis time</td>
<td align="left" valign="top">&lt;1 minute*</td>
</tr>
<tr>
<td align="left" valign="top">*Adjustable</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					