<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Photometer &#8211; Vinca Labtech</title>
	<atom:link href="https://www.vincalabtech.com/product-category/photometer/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.vincalabtech.com</link>
	<description></description>
	<lastBuildDate>Thu, 28 May 2026 09:24:38 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://www.vincalabtech.com/wp-content/uploads/2026/03/cropped-vinca-logo-set-0155-50x50.jpg</url>
	<title>Photometer &#8211; Vinca Labtech</title>
	<link>https://www.vincalabtech.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MD 640 Photometer</title>
		<link>https://www.vincalabtech.com/product/md-640-photometer/</link>
					<comments>https://www.vincalabtech.com/product/md-640-photometer/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Mon, 25 May 2026 12:32:59 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=4543</guid>

					<description><![CDATA[Featuring the ability to measure PTSA and Fluorescein, over 120 preprogrammed photometric tests and Bluetooth® interface for data transfer, the MD 640 is the ultimate testing device for testing the water
quality of a Boiler or Cooling Tower system.
<ul>
 	<li>PTSA and Fluorescein testing capabilities</li>
 	<li>All of the colorimetric tests a Boiler or Cooling Water Technician would need - in one device</li>
 	<li>Rugged, but lightweight, it is ideal for use out in the field</li>
</ul>]]></description>
										<content:encoded><![CDATA[<p><strong style="font-size: 18px;">Technical Specifications &#8211;</strong></p>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Optics</td>
<td>LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Wavelength range: 430 nm IF Δλ = 5 nm 530 nm IF Δλ = 5 nm 560 nm IF Δλ = 5 nm 580 nm IF Δλ = 5 nm 610 nm IF Δλ = 6 nm 660 nm IF Δλ = 5 nm IF = interference filter</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td>± 1 nm</td>
</tr>
<tr>
<td>Photometric Accuracy</td>
<td>2 % FS (T = 20 °C – 25 °C)</td>
</tr>
<tr>
<td>Suitable Vials</td>
<td>Multi vial 10 mm Round Cuvettes 13 mm Round Cuvettes 16 mm Round Cuvettes 24 mm</td>
</tr>
<tr>
<td>Display</td>
<td>Graphic-display</td>
</tr>
<tr>
<td>Interfaces</td>
<td>Bluetooth</td>
</tr>
<tr>
<td>Operation</td>
<td>Acid and solvent resistant, touch-sensitive keypad with audible feedback via integrated beeper</td>
</tr>
<tr>
<td>Auto – OFF</td>
<td>Yes</td>
</tr>
<tr>
<td>Updates</td>
<td>Software updates via internet</td>
</tr>
<tr>
<td>Internal Storage</td>
<td>approx. 500 data sets</td>
</tr>
<tr>
<td>Power Supply</td>
<td>4 batteries (Mignon AA/LR6)</td>
</tr>
<tr>
<td>Battery Life Time</td>
<td>approx. 26 h</td>
</tr>
<tr>
<td>Beeper</td>
<td>existing</td>
</tr>
<tr>
<td>Portability</td>
<td>Benchtop</td>
</tr>
<tr>
<td>Environmental Conditions</td>
<td>5 – 40 °C at max. 30 – 90 % Conditions rel. humidity (non condensing)</td>
</tr>
<tr>
<td>IP Rating</td>
<td>IP 67</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE</td>
</tr>
<tr>
<td>Languages User Interface</td>
<td>German, English, French, Spanish, Italian, Portuguese, Polish, Indonesian</td>
</tr>
<tr>
<td>Dimensions</td>
<td>95 x 45 x 210 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>450 g</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/md-640-photometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MD 610 Photometer</title>
		<link>https://www.vincalabtech.com/product/md-610-photometer/</link>
					<comments>https://www.vincalabtech.com/product/md-610-photometer/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Mon, 25 May 2026 12:24:42 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=4540</guid>

					<description><![CDATA[The MD 610 multi-parameter photometer features a Bluetooth® interface which allows for the sending and sharing of testing data directly from the field. Pre-programmed with over 120 water testing parameters and ranges, it is the ideal field instrument for a variety of applications and industries.
<ul>
 	<li>Easily transfer testing data directly from the field using the AquaLX app</li>
 	<li>Portable instrument for use in the lab, plant or out in the field</li>
 	<li>Multi-Parameter Testing device combines all of the key water testing parameters and testing ranges</li>
</ul>]]></description>
										<content:encoded><![CDATA[<p><strong style="font-size: 18px;">Technical Specifications &#8211;</strong></p>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Optics</td>
<td>LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Wavelength range: 430 nm IF Δλ = 5 nm 530 nm IF Δλ = 5 nm 560 nm IF Δλ = 5 nm 580 nm IF Δλ = 5 nm 610 nm IF Δλ = 6 nm 660 nm IF Δλ = 5 nm IF = interference filter</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td>± 1 nm</td>
</tr>
<tr>
<td>Photometric Accuracy</td>
<td>2 % FS (T = 20 °C – 25 °C)</td>
</tr>
<tr>
<td>Suitable Vials</td>
<td>Multi vial 10 mm</p>
<p>Round Cuvettes 13 mm</p>
<p>Round Cuvettes 16 mm</p>
<p>Round Cuvettes 24 mm</td>
</tr>
<tr>
<td>Display</td>
<td>Graphic-display</td>
</tr>
<tr>
<td>Interfaces</td>
<td>Bluetooth</td>
</tr>
<tr>
<td>Operation</td>
<td>Acid and solvent resistant, touch-sensitive keypad with audible feedback via integrated beeper</td>
</tr>
<tr>
<td>Auto – OFF</td>
<td>Yes</td>
</tr>
<tr>
<td>Updates</td>
<td>Software updates via internet</td>
</tr>
<tr>
<td>Internal Storage</td>
<td>approx. 500 data sets</td>
</tr>
<tr>
<td>Power Supply</td>
<td>4 batteries (Mignon AA/LR6)</td>
</tr>
<tr>
<td>Battery Life Time</td>
<td>approx. 26 h</td>
</tr>
<tr>
<td>Beeper</td>
<td>existing</td>
</tr>
<tr>
<td>Portability</td>
<td>Benchtop</td>
</tr>
<tr>
<td>Environmental Conditions</td>
<td>5 – 40 °C at max. 30 – 90 % Conditions rel. humidity (non condensing)</td>
</tr>
<tr>
<td>IP Rating</td>
<td>IP 67</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE</td>
</tr>
<tr>
<td>Languages User Interface</td>
<td>German, English, French, Spanish, Italian, Portuguese, Polish, Indonesian</td>
</tr>
<tr>
<td>Dimensions</td>
<td>95 x 45 x 210 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>450 g</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/md-610-photometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MD 600 Photometer</title>
		<link>https://www.vincalabtech.com/product/md-600-photometer/</link>
					<comments>https://www.vincalabtech.com/product/md-600-photometer/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Mon, 25 May 2026 12:17:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=4538</guid>

					<description><![CDATA[The MD 600 multi-parameter photometer is pre-programmed with over 120 water testing parameters and ranges. Featuring a rugged, waterproof design, this instrument is the ideal testing solution for a variety of
applications and industries.
<ul>
 	<li>Multi-Parameter Testing device combines all of the key water testing parameters and testing ranges</li>
 	<li>Portable instrument for use in the lab, plant or out in the field</li>
 	<li>User interface is intuitive and easy to navigate</li>
</ul>]]></description>
										<content:encoded><![CDATA[<p><strong style="font-size: 20px;">Technical Specification &#8211;</strong></p>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Optics</td>
<td>LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Wavelength range: 430 nm IF Δλ = 5 nm 530 nm IF Δλ = 5 nm 560 nm IF Δλ = 5 nm 580 nm IF Δλ = 5 nm 610 nm IF Δλ = 6 nm 660 nm IF Δλ = 5 nm IF = interference filter</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td>± 1 nm</td>
</tr>
<tr>
<td>Photometric Accuracy</td>
<td>2 % FS (T = 20 °C – 25 °C)</td>
</tr>
<tr>
<td>Suitable Vials</td>
<td>Multi vial 10 mm Round Cuvettes 13 mm Round Cuvettes 16 mm Round Cuvettes 24 mm</td>
</tr>
<tr>
<td>Display</td>
<td>Graphic-display</td>
</tr>
<tr>
<td>Interfaces</td>
<td>Infrared</td>
</tr>
<tr>
<td>Operation</td>
<td>Acid and solvent resistant, touch-sensitive keypad with audible feedback via integrated beeper</td>
</tr>
<tr>
<td>Auto – OFF</td>
<td>Yes</td>
</tr>
<tr>
<td>Updates</td>
<td>Software updates via internet</td>
</tr>
<tr>
<td>Internal Storage</td>
<td>Approx. 1000 data sets</td>
</tr>
<tr>
<td>Power Supply</td>
<td>4 batteries (Mignon AA/LR6)</td>
</tr>
<tr>
<td>Battery Life Time</td>
<td>approx. 26 h</td>
</tr>
<tr>
<td>Beeper</td>
<td>existing</td>
</tr>
<tr>
<td>Portability</td>
<td>Benchtop</td>
</tr>
<tr>
<td>Environmental Conditions</td>
<td>5 – 40 °C at max. 30 – 90 % Conditions rel. humidity (non condensing)</td>
</tr>
<tr>
<td>IP Rating</td>
<td>IP 67</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE</td>
</tr>
<tr>
<td>Languages User Interface</td>
<td>German, English, French, Spanish, Italian, Portuguese, Polish, Indonesian</td>
</tr>
<tr>
<td>Dimensions</td>
<td>95 x 45 x 210 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>450 g</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/md-600-photometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MD 200 Photometer</title>
		<link>https://www.vincalabtech.com/product/md-200-photometer/</link>
					<comments>https://www.vincalabtech.com/product/md-200-photometer/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Mon, 25 May 2026 11:17:11 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=4532</guid>

					<description><![CDATA[Versatile, compact and: The benchtop photometer MD 200 combines high-quality interference filters with long-term stable LEDs as light sources in a high-precision optic. The result: precise measurement results at all times - no matter where you use it.
<ul>
 	<li>Scroll memory</li>
 	<li>Automatic switch-off</li>
 	<li>Real-Time-Clock and date</li>
 	<li>Calibration mode indicator</li>
</ul>]]></description>
										<content:encoded><![CDATA[<p><strong style="font-size: 18px;">Technical Specification &#8211;</strong></p>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Optics</td>
<td>LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm Δλ = 5 nm 530 nm Δλ = 5 nm 560 nm Δλ = 5 nm 610 nm Δλ = 6 nm</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td>± 1 nm</td>
</tr>
<tr>
<td>Photometric Range</td>
<td>-2600 &#8211; 2600 mAbs</td>
</tr>
<tr>
<td>Photometric Accuracy</td>
<td>3 % FS (T = 20 °C – 25 °C)</td>
</tr>
<tr>
<td>Operation</td>
<td>Foil keypad</td>
</tr>
<tr>
<td>Display</td>
<td>backlit LCD (on keypress)</td>
</tr>
<tr>
<td>Suitable Vials</td>
<td>Round Cuvettes 24 mm</td>
</tr>
<tr>
<td>Calibration</td>
<td>Factory calibration and user calibration. Reset to factory calibration possible.</td>
</tr>
<tr>
<td>Interfaces</td>
<td>Infrared</td>
</tr>
<tr>
<td>Internal Storage</td>
<td>internal ring memory for 16 data sets</td>
</tr>
<tr>
<td>Power Supply</td>
<td>4 batteries (AA)</td>
</tr>
<tr>
<td>Battery Life Time</td>
<td>approx. 53 hours</td>
</tr>
<tr>
<td>Auto – OFF</td>
<td>Yes</td>
</tr>
<tr>
<td>Clock</td>
<td>Real Time Clock and Date</td>
</tr>
<tr>
<td>Portability</td>
<td>Portable</td>
</tr>
<tr>
<td>Environmental Conditions</td>
<td>temperature: 5 &#8211; 40 °C rel. humidity: 30 &#8211; 90 % (non condensing)</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE</td>
</tr>
<tr>
<td>Protection Class</td>
<td>IP 68</td>
</tr>
<tr>
<td>Dimensions</td>
<td>110 x 55 x 190 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>455 g</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/md-200-photometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MD 150 Multiparameter Photometer</title>
		<link>https://www.vincalabtech.com/product/md-150-multiparameter-photometer/</link>
					<comments>https://www.vincalabtech.com/product/md-150-multiparameter-photometer/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Mon, 25 May 2026 09:14:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=4528</guid>

					<description><![CDATA[<strong>Next generation in water testing:</strong>
• Wireless (NFC) and wired (USB-C) data transfer options
• Free Software and App for easy data management
• Enhanced optics for faster operation
• One Time Zero (OTZ) for more convenience and time efficiency
• Intuitive user interface with easy-use icons and animations
• Exceptional durability to withstand demanding conditions]]></description>
										<content:encoded><![CDATA[<p><strong style="font-size: 20px;">Perfect for a wide range of applications &#8211;</strong><br />
<strong>• Multiparameter combinations</strong><br />
The MD150 provides essential parameters for pool water monitoring and disinfection control, including Chlorine, Bromine, Ozone, Chlorine Dioxide, pH, Cyanuric Acid, Alkalinity, and Calcium Hardness.</p>
<p><strong>• Factory programmed methods</strong><br />
The MD150 comes with pre-programmed methods for pool<br />
and various other applications, ready to use out of the box.</p>
<p><strong>• Flexible reagent options: compatible with tablets, powder or liquid</strong><br />
Compatible with various reagent types, simply select your<br />
preferred reagent in the settings, and the method list will<br />
display only the relevant options.</p>
<p><strong style="font-size: 20px;">Instant Data Management</strong><br />
<strong>• Data transfer – NFC / USB-C</strong><br />
Easily transfer data wirelessly via NFC to the AquaLX® app or via USB-C cable to Lovibond® Data Expert. Data can be exported in CSV format for use in programs like Excel.</p>
<p><strong>• GLP (Good Laboratory Practice) compliance</strong><br />
The MD150 automatically records and saves a protocol for every change, ensuring data quality and integrity by tracking any adjustments that could impact measurement results.</p>
<p><strong>• Automatic data storage</strong><br />
The MD150 automatically stores the last 100 readings and protocols with a time/date stamp and retains the data even during battery changes.</p>
<p><strong>• Keep your instrument up to date</strong><br />
Easily update the firmware and methods in seconds using Lovibond® Data Expert. Updates are available on the instrument’s webpage.</p>
<p><strong>• User defined method</strong><br />
With the free of charge Lovibond® Data Expert, you can create custom methods.</p>
<p><strong style="font-size: 20px;">Robust design for reliable performance</strong><br />
<strong>• Built for durability</strong><br />
The MD150 features a durable design with rubber-protected sides ensuring reliability even in demanding environments. With its IP67 rating, the instrument offers full protection against dust and water immersion.</p>
<p><strong>• Ergonomic design</strong><br />
The MD150 is a compact, handheld instrument ideal for the use of the poolside, in the field, or in the lab. Its compact size and side protections ensure a firm grip, while rubber feet prevent slipping, enabling for single-handed operation.</p>
<p><strong style="font-size: 20px;">Effortless operation and precision</strong><br />
<strong>• Quick and accurate results</strong><br />
The innovative optical system of the MD150 provides exceptional accuracy and fast results, delivering precise<br />
measurements in record time.</p>
<p><strong>• One-Time-Zero function</strong><br />
Save operation time with the One-Time-Zero function, which remains valid for up to 8 hours unless the instrument is turned off.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/md-150-multiparameter-photometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>MD110 Photometer</title>
		<link>https://www.vincalabtech.com/product/md110-photometer/</link>
					<comments>https://www.vincalabtech.com/product/md110-photometer/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Thu, 21 May 2026 12:13:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=4526</guid>

					<description><![CDATA[<strong>Waterproof Design</strong>

The IP 68 design of this instrument ensures that the MD 110 remains
water tight for up to 1 hour at 0.1 meter. Don't worry about dropping
the instrument into a body of water - it floats!

&#160;

<strong>Factory Programmed</strong>

All MD 110 instruments are supplied ready to use with up to 14 calibration curves. All you need to do is select the test you need, prepare
your sample and test!
<ul>
 	<li>Bluetooth® -Interface</li>
 	<li>Scroll Memory</li>
 	<li>Automatic switch-off</li>
 	<li>Calibration mode indicator</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h3>Technical Data &#8211;</h3>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Optics</td>
<td>LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used.</td>
</tr>
<tr>
<td>Wavelength specifications of interference filters</td>
<td>430 nm Δλ = 5 nm 530 nm Δλ = 5 nm 560 nm Δλ = 5 nm 580 nm Δλ = 5 nm 610 nm Δλ = 6 nm 660 nm Δλ = 5 nm</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td>± 1</td>
</tr>
<tr>
<td>Photometric Range</td>
<td>-2600 &#8211; 2600 mAbs</td>
</tr>
<tr>
<td>Photometric Accuracy</td>
<td>3 % FS (T = 20 °C – 25 °C)</td>
</tr>
<tr>
<td>Operation</td>
<td>Foil keypad</td>
</tr>
<tr>
<td>Display</td>
<td>backlit LCD (on keypress)</td>
</tr>
<tr>
<td>Suitable Vials</td>
<td>Round Cuvettes 24 mm</td>
</tr>
<tr>
<td>Calibration</td>
<td>factory calibration and user calibration. Reset to factory calibration possible</td>
</tr>
<tr>
<td>Interfaces</td>
<td>Bluetooth</td>
</tr>
<tr>
<td>Internal Storage</td>
<td>internal ring memory for 125 data sets</td>
</tr>
<tr>
<td>Power Supply</td>
<td>4 micro batteries (AAA)</td>
</tr>
<tr>
<td>Battery Life Time</td>
<td>approx. 17 hours</td>
</tr>
<tr>
<td>Auto – OFF</td>
<td>Yes</td>
</tr>
<tr>
<td>Clock</td>
<td>Real Time Clock and Date</td>
</tr>
<tr>
<td>Portability</td>
<td>Portable</td>
</tr>
<tr>
<td>Environmental Conditions</td>
<td>temperature: 5 &#8211; 40 °C rel. humidity: 30 &#8211; 90 % (non condensing)</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE</td>
</tr>
<tr>
<td>Protection Class</td>
<td>IP 68</td>
</tr>
<tr>
<td>Dimensions</td>
<td>155 x 75 x 35 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>260 g</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/md110-photometer/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Photometer MD-50</title>
		<link>https://www.vincalabtech.com/product/photometer-md-50/</link>
					<comments>https://www.vincalabtech.com/product/photometer-md-50/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Thu, 21 May 2026 11:44:30 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=4522</guid>

					<description><![CDATA[The MD50 series combines precise single-parameter photometry with maximum user-friendliness, designed to meet the daily challenges of water analysis.
Thanks to the intuitive, language-independent user interface with clear symbols and helpful animations, the instrument can be operated quickly and confidently, regardless of language barriers. The integrated favourites function ensures efficient workflows by making frequently used methods directly available at all times.
Robustly built for demanding outdoor use, the MD50 series delivers reliable performance even under the toughest conditions.]]></description>
										<content:encoded><![CDATA[<h3 style="text-align: center;">Delivery Content</h3>
<p style="text-align: center;">• MD50<br />
• 2 x AA Batteries<br />
• Screwdriver<br />
• 3 x Stiring rods<br />
• 3 x 24 mm Vials with lid<br />
• Syringe<br />
• Cleaning brush<br />
• USB-C to USB-A Cable<br />
• Instruction manual<br />
• Reagents (depends on variant)<br />
liquid, powder or tablets</p>
<h3 style="text-align: center;">Versions &#8211;</h3>
<table>
<thead>
<tr>
<th>MD50 Variants</th>
<th align="right">Method No.</th>
<th>Method</th>
<th>Measuring range</th>
<th>Type of reagents</th>
<th align="right">Code (comp. Kit)</th>
</tr>
</thead>
<tbody>
<tr>
<td>MD50 Chlorine</td>
<td align="right">M100</td>
<td>Cl (free, total, comb.)</td>
<td>0,02–6 mg/L Cl2</td>
<td>Tablets</td>
<td align="right">280100</td>
</tr>
<tr>
<td>MD50 Chlorine</td>
<td align="right">M101</td>
<td>Cl (free, total, comb.)</td>
<td>0,02–4 mg/L Cl2</td>
<td>Liquid</td>
<td align="right">280102</td>
</tr>
<tr>
<td>MD50 Chlorine</td>
<td align="right">M103</td>
<td>Cl HR (free, total, comb.)</td>
<td>0,1–10 mg/L Cl2</td>
<td>Tablets</td>
<td align="right">280105</td>
</tr>
<tr>
<td>MD50 Chlorine</td>
<td align="right">M110</td>
<td>Cl (free, total, comb.)</td>
<td>0,02–2 mg/L Cl2</td>
<td>Powder</td>
<td align="right"></td>
</tr>
<tr>
<td>MD50 Chlorine</td>
<td align="right">M112</td>
<td>Cl HR (free, total, comb.)</td>
<td>0,1–10 mg/L Cl2</td>
<td>Powder</td>
<td align="right"></td>
</tr>
<tr>
<td>MD50 Chlorine Dioxide</td>
<td align="right">M120</td>
<td>ClO2,ClF (ClO2), ClT (ClO2)</td>
<td>0,02–11 mg/L ClO2</td>
<td>Tablets</td>
<td align="right">280120</td>
</tr>
<tr>
<td>MD50 Chlorine Dioxide</td>
<td align="right">M122</td>
<td>ClO2, ClF (ClO2)</td>
<td>0,04–3,8 mg/L ClO2</td>
<td>Powder</td>
<td align="right">280125</td>
</tr>
<tr>
<td>MD50 Ozone</td>
<td align="right">M300</td>
<td>O3, O3 (ClT)</td>
<td>0,02–2 mg/L O3</td>
<td>Tablets</td>
<td align="right">280130</td>
</tr>
<tr>
<td>MD50 Ozone</td>
<td align="right">M301</td>
<td>O3, O3 (ClT)</td>
<td>0,015–1,2 mg/L O3</td>
<td>Powder</td>
<td align="right">280135</td>
</tr>
<tr>
<td>MD50 Chlorine HR (KI)</td>
<td align="right">M105</td>
<td>Cl HR (KI)</td>
<td>5–200 mg/L Cl2</td>
<td>Tablets</td>
<td align="right">280140</td>
</tr>
<tr>
<td>MD50 Chlorine HR (KI)</td>
<td align="right">M212</td>
<td>NaOCl</td>
<td>0,2–16 % NaOCl</td>
<td>Tablets</td>
<td align="right"></td>
</tr>
<tr>
<td>MD50 Monochloramine</td>
<td align="right">M63</td>
<td>MCA, NH3 (MCA)</td>
<td>0,02–4,5 mg/L Cl2</td>
<td>Powder + Liquid</td>
<td align="right">280150</td>
</tr>
<tr>
<td>MD50 Monochloramine</td>
<td align="right">M64</td>
<td>MCA, Cl2 (MCA)</td>
<td>0,02–4,5 mg/L Cl2</td>
<td>Powder + Liquid</td>
<td align="right"></td>
</tr>
<tr>
<td>MD50 Urea</td>
<td align="right">M390</td>
<td>UREA</td>
<td>0,1–2,5 mg/L CH4N2O</td>
<td>Liquid</td>
<td align="right">280160</td>
</tr>
<tr>
<td>MD50 Urea</td>
<td align="right">M391</td>
<td>UREA</td>
<td>0,2–5 mg/L CH4N2O</td>
<td>Liquid</td>
<td align="right"></td>
</tr>
<tr>
<td>MD50 Suspended Solids</td>
<td align="right">M384</td>
<td>SuS</td>
<td>10–750 mg/L TSS</td>
<td>No reagents</td>
<td align="right">280170</td>
</tr>
<tr>
<td>MD50 Hazen</td>
<td align="right">M204</td>
<td>Hazen</td>
<td>10–500 Pt-Co Units</td>
<td>No reagents</td>
<td align="right">280180</td>
</tr>
<tr>
<td>MD50 Molybdenum</td>
<td align="right">M250</td>
<td>Mo</td>
<td>0,6–30 mg/L Mo</td>
<td>Tablets</td>
<td align="right">280191</td>
</tr>
<tr>
<td>MD50 Molybdenum</td>
<td align="right">M252</td>
<td>Mo HR</td>
<td>0,3–40 mg/L Mo</td>
<td>Powder</td>
<td align="right">280195</td>
</tr>
<tr>
<td>MD50 Copper</td>
<td align="right">M150</td>
<td>Cu (free, total, diff.)</td>
<td>0,05–5 mg/L Cu</td>
<td>Tablets</td>
<td align="right">280200</td>
</tr>
<tr>
<td>MD50 Copper</td>
<td align="right">M152</td>
<td>Cu VLR</td>
<td>0,05–5 mg/L Cu</td>
<td>Powder</td>
<td align="right"></td>
</tr>
<tr>
<td>MD50 Copper</td>
<td align="right">M153</td>
<td>Cu</td>
<td></td>
<td>Powder</td>
<td align="right">280200</td>
</tr>
<tr>
<td>MD50 Phosphate</td>
<td align="right">M320</td>
<td>PO4</td>
<td>0,05–4 mg/L PO4</td>
<td>Tablets</td>
<td align="right">280210</td>
</tr>
<tr>
<td>MD50 Phosphate</td>
<td align="right">M323</td>
<td>PO4</td>
<td>0,06–2,5mg/L PO4</td>
<td>Powder</td>
<td align="right">280215</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p style="text-align: center;"><strong>Accessories</strong><br />
• 24 mm Round cuvette<br />
Set with 5 Pc. (197629) or 12 Pc. (197620)<br />
• Stirring rod Set 10 Pc. (364130)<br />
• Measuring beaker (384801)<br />
• Plastic funnel with handle, white (4710070)</p>
<p style="text-align: center;">• Cuvette stand (418951)<br />
• USB Cable (19820-081)<br />
• Cleaning cloth (197635)<br />
• Cleaning brush (380230)</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/photometer-md-50/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
