<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Spectrophotometer &#8211; Vinca Labtech</title>
	<atom:link href="https://www.vincalabtech.com/product-category/spectrophotometer/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.vincalabtech.com</link>
	<description></description>
	<lastBuildDate>Tue, 02 Jun 2026 14:02:08 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://www.vincalabtech.com/wp-content/uploads/2026/03/cropped-vinca-logo-set-0155-50x50.jpg</url>
	<title>Spectrophotometer &#8211; Vinca Labtech</title>
	<link>https://www.vincalabtech.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Spectrophotometer XD 7500 (UV-VIS)</title>
		<link>https://www.vincalabtech.com/product/spectrophotometer-xd-7500-uv-vis/</link>
					<comments>https://www.vincalabtech.com/product/spectrophotometer-xd-7500-uv-vis/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Fri, 10 Apr 2026 11:39:05 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3301</guid>

					<description><![CDATA[The XD series instruments are ideal for routine and spectral analysis. As true all-rounders, the XD 7000 and XD 7500 facilitate work routines, especially with automatic method recognition using barcodes, automatic cell recognition and more than 170 pre-programmed methods. In addition to analytical quality control, they also support Good Labor Practice (GLP). The instruments are available together with bar-coded test tubes and a wide range of accessories from a single source - which is also easy on your wallet. High-quality reference beam optics, usability, easy handling and multilingual global applicability round off the versatility of the VIS and UV/VIS spectrophotometers, which are also equipped for flexible on-site use.

&#160;]]></description>
										<content:encoded><![CDATA[<p><strong>Latest technology</strong><br />
The XD 7000 and XD 7500 spectrophotometers are equipped with VIS<br />
respectively UV / VIS reference beam technology.</p>
<p><strong>Automatic test recognition</strong><br />
Each of the more than 170 pre-programmed Lovibond® methods is recognized by barcode as well as the cuvette type.</p>
<p><strong>Analytical quality assurance</strong><br />
Standard procedures for analytical quality assurance support the verification of the photometer, the overall system (including the chemical methodology) and the verification of matrix effects.</p>
<p><strong>Built-in security levels</strong><br />
The devices support the assignment of passwords and the assignment of up to three different levels of rights.</p>
<p><strong>Additional functions</strong><br />
Measurement of transmission and absorption, spectral scan, kinetics analysis, as well as the creation of user-defined methods.</p>
<p><strong>Interfaces for data processing</strong><br />
You want to process your data? With Ethernet, USB B, USB A for external memory, keyboard, barcode scanner and printer different versions are available.</p>
<p>&nbsp;</p>
<p><strong>Technical Data</strong></p>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Optics</td>
<td>Grid monochromator with reference beam and beam splitter after exit slit</td>
</tr>
<tr>
<td>Light Source</td>
<td>Xenon flash lamp (500 million flashes possible)</td>
</tr>
<tr>
<td>Measurement</td>
<td>Concentration, single &amp; multi-wavelength absorbance, % transmission, kinetics, spectra</td>
</tr>
<tr>
<td>Wavelength Range</td>
<td>190–1100 nm</td>
</tr>
<tr>
<td>Wavelength Resolution</td>
<td>1 nm</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td>±1 nm on all Holmium peaks</td>
</tr>
<tr>
<td>Wavelength Reproducibility</td>
<td>Better than 0.5 nm</td>
</tr>
<tr>
<td>Spectral Scope</td>
<td>4 nm</td>
</tr>
<tr>
<td>Photometric Range</td>
<td>-3.3 to +3.3 Abs</td>
</tr>
<tr>
<td>Photometric Resolution</td>
<td>Absorption: 0.001; Transmission: 0.1%</td>
</tr>
<tr>
<td>Photometric Accuracy</td>
<td>0.003 Abs below 0.6 Abs; 0.5% from 0.6–2.0 Abs</td>
</tr>
<tr>
<td>Photometric Reproducibility</td>
<td>0.003 Abs below 0.6 Abs; 0.5% from 0.6–2.0 Abs</td>
</tr>
<tr>
<td>Photometric Linearity</td>
<td>&lt;1% up to 2.0 Abs between 340–900 nm</td>
</tr>
<tr>
<td>Scan Speed</td>
<td>700–2000 nm/min</td>
</tr>
<tr>
<td>Drift</td>
<td>&lt;0.005 Abs/hour after 15 min warm-up</td>
</tr>
<tr>
<td>Stray Light</td>
<td>&lt;0.05% transmission at 340 &amp; 408 nm</td>
</tr>
<tr>
<td>Suitable Vials</td>
<td>Rectangular cuvettes: 10, 20, 50 mm; Round cuvettes: 13, 16, 24 mm</td>
</tr>
<tr>
<td>Display</td>
<td>7&#8243; high contrast color graphic display</td>
</tr>
<tr>
<td>Interfaces</td>
<td>Ethernet, USB-B, USB-A (External Memory), Keypad, Barcode Scanner, PCL Printer</td>
</tr>
<tr>
<td>Operation</td>
<td>Membrane Keyboard</td>
</tr>
<tr>
<td>Automatic Cuvette Recognition</td>
<td>Round: 13,16,24 mm; Rectangular: 10,20,50 mm</td>
</tr>
<tr>
<td>Auto-OFF</td>
<td>Yes</td>
</tr>
<tr>
<td>Test Recognition</td>
<td>Via internal barcode reader</td>
</tr>
<tr>
<td>Programmability</td>
<td>Up to 100 user programs, 20 user profiles, &gt;150 preprogrammed methods</td>
</tr>
<tr>
<td>Auto-Check</td>
<td>Self-test of memory, processor, interface, lamp &amp; wavelength calibration</td>
</tr>
<tr>
<td>LIMS Compatibility</td>
<td>ASCII, .csv files</td>
</tr>
<tr>
<td>Internal Storage</td>
<td>Approx. 5000 datasets</td>
</tr>
<tr>
<td>Security</td>
<td>Password protection with Guest/User/Admin levels</td>
</tr>
<tr>
<td>Power Drain</td>
<td>100–240V, 50/60Hz</td>
</tr>
<tr>
<td>Power Supply</td>
<td>Buffer batteries (4 × AA), power supply cable</td>
</tr>
<tr>
<td>Portability</td>
<td>Benchtop</td>
</tr>
<tr>
<td>Environmental Conditions</td>
<td>+10°C to +35°C, ≤75% avg humidity</td>
</tr>
<tr>
<td>Storage Conditions</td>
<td>-25°C to +65°C</td>
</tr>
<tr>
<td>IP Rating</td>
<td>IP30</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE</td>
</tr>
<tr>
<td>Interference Emission</td>
<td>Class B</td>
</tr>
<tr>
<td>Interference Immunity</td>
<td>IEC 61000-4-3</td>
</tr>
<tr>
<td>Tolerance Extension</td>
<td>0.008 E</td>
</tr>
<tr>
<td>Meter Safety</td>
<td>EC Directive 2014/35/EC, EN 61010-1:2010</td>
</tr>
<tr>
<td>User Interface Languages</td>
<td>German, English, French, Spanish, Italian, Portuguese, Polish, Indonesian, Russian, Chinese, Japanese + more</td>
</tr>
<tr>
<td>Full Manual Languages</td>
<td>German, English, Spanish, French, Italian, Portuguese, Chinese, Japanese</td>
</tr>
<tr>
<td>Dimensions</td>
<td>422 × 195 × 323 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>4.5 kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/spectrophotometer-xd-7500-uv-vis/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Spectrophotometer XD 7000 (VIS)</title>
		<link>https://www.vincalabtech.com/product/spectrophotometer-xd-7000-vis/</link>
					<comments>https://www.vincalabtech.com/product/spectrophotometer-xd-7000-vis/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Fri, 10 Apr 2026 11:39:03 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3300</guid>

					<description><![CDATA[The XD series instruments are ideal for routine and spectral analysis. As true all-rounders, the XD 7000 and XD 7500 facilitate work routines, especially with automatic method recognition using barcodes, automatic cell recognition and more than 170 pre-programmed methods. In addition to analytical quality control, they also support Good Labor Practice (GLP). The instruments are available together with bar-coded test tubes and a wide range of accessories from a single source - which is also easy on your wallet. High-quality reference beam optics, usability, easy handling and multilingual global applicability round off the versatility of the VIS and UV/VIS spectrophotometers, which are also equipped for flexible on-site use.]]></description>
										<content:encoded><![CDATA[<p><strong style="font-size: 18px;">Technical Specifications &#8211;</strong></p>
<table style="height: 1498px;" width="836">
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Optics</td>
<td>Grid monochromator with reference beam and beam splitter after exit slit</td>
</tr>
<tr>
<td>Light Source</td>
<td>Tungsten halogen lamp</td>
</tr>
<tr>
<td>Measurement</td>
<td>Concentration, single &amp; multi-wavelength absorbance, % transmission, kinetics, spectra</td>
</tr>
<tr>
<td>Wavelength Range</td>
<td>320–1100 nm</td>
</tr>
<tr>
<td>Wavelength Resolution</td>
<td>1 nm</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td>±1 nm on all Holmium peaks</td>
</tr>
<tr>
<td>Spectral Scope</td>
<td>4 nm</td>
</tr>
<tr>
<td>Photometric Range</td>
<td>-3.3 to +3.3 Abs</td>
</tr>
<tr>
<td>Photometric Resolution</td>
<td>Absorption: 0.001; Transmission: 0.1%</td>
</tr>
<tr>
<td>Photometric Reproducibility</td>
<td>0.003 Abs below 0.6 Abs; 0.5% from 0.6–2.0 Abs</td>
</tr>
<tr>
<td>Photometric Linearity</td>
<td>&lt;1% up to 2.0 Abs between 340–900 nm</td>
</tr>
<tr>
<td>Scan Speed</td>
<td>700–2000 nm/min</td>
</tr>
<tr>
<td>Drift</td>
<td>&lt;0.005 Abs/hour after 15 minutes warm-up</td>
</tr>
<tr>
<td>Stray Light</td>
<td>&lt;0.1% transmission at 340 &amp; 408 nm</td>
</tr>
<tr>
<td>Suitable Vials</td>
<td>Rectangular cuvettes: 10, 20, 50 mm; Round cuvettes: 13, 16, 24 mm</td>
</tr>
<tr>
<td>Display</td>
<td>7&#8243; high contrast color graphic display</td>
</tr>
<tr>
<td>Interfaces</td>
<td>Ethernet, USB-B, USB-A (External Memory), Keypad, Barcode Scanner, PCL Compatible Printer</td>
</tr>
<tr>
<td>Operation</td>
<td>Membrane Keyboard</td>
</tr>
<tr>
<td>Automatic Cuvette Recognition</td>
<td>Round: 13,16,24 mm; Rectangular: 10,20,50 mm</td>
</tr>
<tr>
<td>Test Recognition</td>
<td>Internal barcode reader</td>
</tr>
<tr>
<td>Auto-Check</td>
<td>Self-test of memory, processor, interface, filter lamp &amp; wavelength calibration</td>
</tr>
<tr>
<td>LIMS Compatibility</td>
<td>ASCII, .csv files</td>
</tr>
<tr>
<td>Internal Storage</td>
<td>Approx. 5000 datasets (method, user ID, date, result)</td>
</tr>
<tr>
<td>Security</td>
<td>Password protection with Guest/User/Admin levels</td>
</tr>
<tr>
<td>Power Drain</td>
<td>100–240V, 50/60Hz</td>
</tr>
<tr>
<td>Power Supply</td>
<td>Buffer batteries (4 × AA), power supply unit with cable</td>
</tr>
<tr>
<td>Portability</td>
<td>Benchtop</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE</td>
</tr>
<tr>
<td>IP Protection Class</td>
<td>EN 60529</td>
</tr>
<tr>
<td>Interference Emission</td>
<td>Class B</td>
</tr>
<tr>
<td>Interference Immunity</td>
<td>IEC 61000-4-3</td>
</tr>
<tr>
<td>Tolerance Extension</td>
<td>0.008 E</td>
</tr>
<tr>
<td>Meter Safety</td>
<td>EC Directive 2014/35/EC, EN 61010-1:2010</td>
</tr>
<tr>
<td>User Interface Languages</td>
<td>German, English, French, Spanish, Italian, Portuguese, Polish, Indonesian, Russian, Chinese, Japanese, Dutch, Swedish, Norwegian, Czech, Romanian, Macedonian, Slovenian, Hungarian, Turkish, Korean, Vietnamese, Thai, Serbian, Malaysian, Danish, Bulgarian</td>
</tr>
<tr>
<td>Quick Start Guide Languages</td>
<td>German, English, French, Spanish, Italian, Portuguese, Polish, Indonesian, Russian, Chinese, Japanese, Dutch, Swedish, Norwegian, Czech, Romanian, Macedonian, Slovenian, Hungarian, Turkish, Korean, Vietnamese, Thai, Serbian, Malaysian, Danish, Bulgarian</td>
</tr>
<tr>
<td>Full User Manual Languages</td>
<td>German, English, Spanish, French, Italian, Portuguese, Chinese, Japanese</td>
</tr>
<tr>
<td>Dimensions</td>
<td>16.61 × 7.68 × 12.72 in</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/spectrophotometer-xd-7000-vis/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Atomic Absorption Spectrophotometer AA8000</title>
		<link>https://www.vincalabtech.com/product/atomic-absorption-spectrophotometer-aa8000/</link>
					<comments>https://www.vincalabtech.com/product/atomic-absorption-spectrophotometer-aa8000/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Tue, 07 Apr 2026 12:11:11 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3151</guid>

					<description><![CDATA[The Fully Automatic True Double Beam Atomic Absorption Spectrophotometer AA8000 by Labindia Analytical provides precise elemental analysis with its true double beam design for superior accuracy and stability. It supports flame, graphite furnace, and vapor generation techniques. Its automated system ensures efficient operation, enhanced by advanced safety features and comprehensive data management, making it ideal for various applications.]]></description>
										<content:encoded><![CDATA[<p><strong style="font-size: 18px;">Technical Specifications &#8211;</strong></p>
<p>Flame System &#8211;</p>
<p>Instrument can be configured with Flame, Graphite or Integrated Flame &amp; Graphite (interchanged using Software)</p>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Wavelength Range</td>
<td>185nm – 915nm</td>
</tr>
<tr>
<td>Optics</td>
<td>Double Beam, Sealed &amp; Vibration free optical System with a reflective optical compartment</td>
</tr>
<tr>
<td>Detector</td>
<td>PMT (Wide Range)</td>
</tr>
<tr>
<td>Monochromator</td>
<td>Czerny-turner type with Holographic Grating of 1800 lines/mm and Reciprocal Linear Dispersion better than 1.6 nm/mm, focal length 300mm.</td>
</tr>
<tr>
<td>Spectral Bandwidth</td>
<td>Adjustable slit from 0.1 nm. to 2 nm. (software selectable)</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td>± 0.15nm</td>
</tr>
<tr>
<td>Wavelength Reproducibility</td>
<td>&lt; 0.05nm</td>
</tr>
<tr>
<td>Resolution</td>
<td>0.2nm ± 0.02nm</td>
</tr>
<tr>
<td>Baseline Stability</td>
<td>0.005A/30min</td>
</tr>
<tr>
<td>Sensitivity (Cu)</td>
<td>&gt;0.9 Absorbance or better for 5 ppm Cu solution-12</td>
</tr>
<tr>
<td>Detection Limit</td>
<td>Cu &lt; 0.004 μg/ml (flame) Cd &lt; 0.4 x 10 g (graphite furnace)</td>
</tr>
<tr>
<td>Repeatability</td>
<td>Cu &lt; 0.7% ( Air/Acetylene flame) Ba &lt; 1.0% ( Nitrous oxide/Acetylene flame) Cu &lt; 2.0% Cd &lt; 2.0% (Graphite Furnace)</td>
</tr>
<tr>
<td>Background Correction</td>
<td>Deuterium Arc / Self reversal upto 2.5 Absorbance</td>
</tr>
<tr>
<td>Characteristic Concentration</td>
<td>Cu &lt; 0.02 μg/ml, Ba &lt; 0.15 mg/ml (NO/Acetylene)</td>
</tr>
<tr>
<td>Burner Heads</td>
<td>2</td>
</tr>
<tr>
<td>Nebuliser</td>
<td>High Efficiency Nebuliser</td>
</tr>
<tr>
<td>Burner Head</td>
<td>Titanium Alloy</td>
</tr>
<tr>
<td>Atomization Chamber</td>
<td>Corrosion-resistant material</td>
</tr>
<tr>
<td>Position Adjustment</td>
<td>Automatic changeover (AA8000GF) Manual (AA8000F) Automatic Setting of Optimum Height for Flame Burner. Burner movement in horizontal &amp; vertical direction by software.</td>
</tr>
<tr>
<td>Safety Functions (Interlocks)</td>
<td>Burner Identification, Flame Sensor, Gas leak Sensor, Low Gas Pressure Sensor, Drain Trap Sensor, Power Loss Protection, Circulation Water (graphite), Over Temperature Sensor (graphite)</td>
</tr>
</tbody>
</table>
<p><strong>Graphite System</strong></p>
<ul>
<li>Graphite Tubes are pyrolytically coated &amp; transversely heated upto 3000˚C</li>
<li>Platform tubes supplied as standard, capable of accepting volumes upto 20 µL</li>
<li>Programmable graphite furnace upto 10 stages which can be set &amp; stored using Software</li>
<li>Replacement of Graphite tube performed by a simple command using Software</li>
<li>Graphite tube cooling by additional water circulatory system</li>
<li>Cd Sensitivity: 4&#215;10 gm</li>
</ul>
<p><strong>Safety Features &#8211;</strong></p>
<ol>
<li>Argon Gas pressure sensor</li>
<li>Water Flow sensor</li>
<li>Over Temperature sensor</li>
<li>Broken Graphite Tube protection</li>
</ol>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/atomic-absorption-spectrophotometer-aa8000/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>UV3092 Spectrophotometer</title>
		<link>https://www.vincalabtech.com/product/labindia-uv3092-spectrophotometer-with-pmt-detector/</link>
					<comments>https://www.vincalabtech.com/product/labindia-uv3092-spectrophotometer-with-pmt-detector/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Tue, 07 Apr 2026 12:03:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3149</guid>

					<description><![CDATA[The UV3092 Spectrophotometer offers precise wavelength resolution with a continuous variable bandwidth from 0.1 to 5nm. Its double beam design and high-quality holographic grating ensure excellent sensitivity for closely spaced wavelengths. The modular sample compartment accommodates various accessories, while user-friendly lamp replacement and the UV-Win software simplify operation and data processing.]]></description>
										<content:encoded><![CDATA[<p><strong>Technical Specification &#8211;</strong></p>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Features and Specifications</td>
<td>Microprocessor based UV/VIS Spectrophotometer display operation on 220V/50Hz.</td>
</tr>
<tr>
<td>Control</td>
<td>Complete control through PC with UV-win Software.</td>
</tr>
<tr>
<td>Optics</td>
<td>High end Double Beam optics with holographic grating in Czerny-Turner mounting.</td>
</tr>
<tr>
<td>Wavelength range</td>
<td>190 &#8211; 900nm</td>
</tr>
<tr>
<td>Spectral Bandwidth</td>
<td>Continuous changeable slit from 0.1 &#8211; 5 nm</td>
</tr>
<tr>
<td>Detector</td>
<td>PMT</td>
</tr>
<tr>
<td>Stray light</td>
<td>≤0.01% T (220nm Nal, 340nm NaNo2)</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td>± 0.3nm (automatic wavelength correction)</td>
</tr>
<tr>
<td>Wavelength Repeatability</td>
<td>&lt; 0.1nm</td>
</tr>
<tr>
<td>Photometric range</td>
<td>-4A ~ 4A</td>
</tr>
<tr>
<td>Photometric Accuracy</td>
<td>±0.002Abs (0-0.5Abs); ±0.004Abs (0.5-1.0Abs); ±0.3% T (0-100%T)</td>
</tr>
<tr>
<td>Photometric Repeatability</td>
<td>±0.001 Abs (0-0.5 Abs); ± 0.002Abs (0.5–1.0Abs)</td>
</tr>
<tr>
<td>Noise</td>
<td>±0.0004Abs</td>
</tr>
<tr>
<td>Drift</td>
<td>≤0.0004A/1h</td>
</tr>
<tr>
<td>Baseline Flatness</td>
<td>0.001A</td>
</tr>
<tr>
<td>Communication Interface</td>
<td>USB</td>
</tr>
<tr>
<td>Lamps</td>
<td>High intensity Tungsten Halogen and Deuterium lamp with automatic changeover.</td>
</tr>
<tr>
<td>Validation &amp; Security</td>
<td>Built in validation program diagnostic and security functions.</td>
</tr>
<tr>
<td>Operational modes</td>
<td>Photometric, quantitative, Spectrum scan, Kinetics, DNA and Protein. UV-Win software adds functions such as 3D Spectrum analysis, GLP/GMP protocol.</td>
</tr>
<tr>
<td>Sample Compartment</td>
<td>Large sample compartment with built in 1 Reference and 1 Sample holder compatible with wide range of accessories.</td>
</tr>
<tr>
<td>UV WIN Software Version</td>
<td>5.0 Windows based and supports Windows XP operating system. Offers single point control, measurement, analysis of UV-VIS Spectrophotometer from PC.</td>
</tr>
<tr>
<td>Standard Features</td>
<td>Client Management</td>
</tr>
<tr>
<td>Standard Features</td>
<td>Quality Control</td>
</tr>
<tr>
<td>Standard Features</td>
<td>3D Spectra Graph</td>
</tr>
<tr>
<td>Standard Features</td>
<td>Multi-users management</td>
</tr>
<tr>
<td>Standard Features</td>
<td>Operation log and Audit Trail for security guarantee as well as compliant to GLP and Pharmacopoeial requirement.</td>
</tr>
<tr>
<td>Standard Features</td>
<td>Data File Incorporation and Instrument Validation – includes 6 items: “Wavelength accuracy”, “Photometric accuracy”, “Stray light”, “Noise”, “Baseline flatness”, and “Stability”.</td>
</tr>
<tr>
<td>Design</td>
<td>Compact design with small footprint</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/labindia-uv3092-spectrophotometer-with-pmt-detector/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>UV 3200TS Spectrophotometer (Touchscreen)</title>
		<link>https://www.vincalabtech.com/product/labindia-uv-3200ts-spectrophotometer-touchscreen/</link>
					<comments>https://www.vincalabtech.com/product/labindia-uv-3200ts-spectrophotometer-touchscreen/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Tue, 07 Apr 2026 12:03:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3143</guid>

					<description><![CDATA[Discover the UV 3200 TS, a high-performance UV/Vis spectrophotometer designed for demanding applications. With its advanced optical system, precise measurements, and versatile features, the UV 3200 TS is the ideal choice for researchers and professionals seeking exceptional accuracy and reliability.]]></description>
										<content:encoded><![CDATA[<p><strong style="font-size: 18px;">Technical Specification &#8211;</strong></p>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Optical system</td>
<td>Double beam with Czerny-Turner Monochromator</td>
</tr>
<tr>
<td>Light source</td>
<td>Tungsten and Deuterium Lamp, pre-aligned</td>
</tr>
<tr>
<td>Spectral bandwidth</td>
<td>0.5, 1, 2, 4nm</td>
</tr>
<tr>
<td>Wavelength range</td>
<td>190 ~ 1100 nm</td>
</tr>
<tr>
<td>Wavelength accuracy</td>
<td>±0.3 nm ( full range 190nm &#8211; 1100nm)</td>
</tr>
<tr>
<td>Wavelength repeatability</td>
<td>0.1 nm</td>
</tr>
<tr>
<td>Wavelength resolution</td>
<td>0.1 nm</td>
</tr>
<tr>
<td>Scanning speed</td>
<td>1 to 3000nm/min variable</td>
</tr>
<tr>
<td>Photometric range</td>
<td>-4 to 4.0A</td>
</tr>
<tr>
<td>Photometric accuracy</td>
<td>0.5A ± 0.002 A</td>
</tr>
<tr>
<td>Noise</td>
<td>0.000016 Abs RMS@500nm</td>
</tr>
<tr>
<td>Drift</td>
<td>&lt; 0.0002 Abs/H @ 500 nm</td>
</tr>
<tr>
<td>Baseline flatness</td>
<td>±0.001 A</td>
</tr>
<tr>
<td>Stray light</td>
<td>0.02 @ 220nm KCL 198nm = 1% T</td>
</tr>
<tr>
<td>Optional Accessory</td>
<td>Specular Reflection Accessory, Integrating Sphere 60mm / 100mm</td>
</tr>
<tr>
<td>Optional Accessory</td>
<td>Automatic 8 Cell Changer, long path cell holder, Peltier Solid Sample holder etc.</td>
</tr>
<tr>
<td>Photometric mode</td>
<td>Photometry, Quantitation, Spectrum, Kinetics</td>
</tr>
<tr>
<td>Detector</td>
<td>Dual Silicon photodiode</td>
</tr>
<tr>
<td>Lamp Interchange Wavelength</td>
<td>Automatic interchange linked to wavelength. The interchange wavelength can be set freely</td>
</tr>
<tr>
<td>Wavelength Slew Rate</td>
<td>6500 nm/min</td>
</tr>
<tr>
<td>Sample cell holder</td>
<td>Pair of 10 mm cell holder upgradable to automatic 8 cell changer</td>
</tr>
<tr>
<td>Display</td>
<td>10.1 Inch IPS colour LCD touch screen, capacitive 10-point touch control (resolution: 1280×800), 2GB memory/64GB SSD storage, 178 degree full view, 16 million colours, high resolutions, 10.1 inch IPS colour. Embedded Operating system, with sealed membrane.</td>
</tr>
<tr>
<td>Software</td>
<td>Complies with the requirement of 21CFR Part 11 with GLP/GMP functions, file management functions.</td>
</tr>
<tr>
<td>Storage</td>
<td>64GB (built-in), unlimited expansion (USB storage, SD card, network storage device)</td>
</tr>
<tr>
<td>Interface</td>
<td>USB-A (extensible; connect USB printers, storages, mice, keyboards and other peripherals)×3, USB-B (PC)×1, RJ 45 (Ethernet)×1, VGA×1, HDMI×1, Bluetooth, WiFi</td>
</tr>
<tr>
<td>Power</td>
<td>100 ~ 240 V AC, 50/60 Hz, 100 W</td>
</tr>
<tr>
<td>Dimension</td>
<td>600450200 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>18 kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/labindia-uv-3200ts-spectrophotometer-touchscreen/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
