<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Uncategorized &#8211; Vinca Labtech</title>
	<atom:link href="https://www.vincalabtech.com/product-category/uncategorized/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.vincalabtech.com</link>
	<description></description>
	<lastBuildDate>Wed, 20 May 2026 10:00:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.1</generator>

<image>
	<url>https://www.vincalabtech.com/wp-content/uploads/2026/03/cropped-vinca-logo-set-0155-50x50.jpg</url>
	<title>Uncategorized &#8211; Vinca Labtech</title>
	<link>https://www.vincalabtech.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>COD Set-Up MD 610</title>
		<link>https://www.vincalabtech.com/product/cod-set-up-md-610/</link>
					<comments>https://www.vincalabtech.com/product/cod-set-up-md-610/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Fri, 10 Apr 2026 12:20:42 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3308</guid>

					<description><![CDATA[The Lovibond<sup>®</sup> COD Setups allow highly sensitive and precise water testing with minimum effort. They measure the ST-COD concentration by photometric detection employing a linear relationship between absorbance and concentration.
After adding the sample to a Lovibond<sup>®</sup> COD tube test (LR, MR according to ISO 15705:2002), it is heated in the reactor for two hours at 150 °C and then analysed in the photometer.
The COD Setups comprise the photometer, 25 tube tests for each of the two lower measuring ranges, a reactor for sample digestion and a vial stand.]]></description>
										<content:encoded><![CDATA[<ul>
<li>ST-COD sealed tubes ready for use</li>
<li>Suppression of chloride interference up to 1000 mg/L (LR &amp; MR) up to 10000 mg/L (HR)</li>
<li>Mercury free tube tests,in absence of chloride interference</li>
<li>4 ranges:
<ul>
<li>Low range: 3 &#8211; 150 mg/L, meets ISO 15705:2002</li>
<li>Middle-low range: 15 &#8211; 300 mg/L, meets ISO 15705:2002</li>
<li>Middle range: 20 &#8211; 1500 mg/L, meets ISO 15705:2002</li>
<li>High range: 200 &#8211; 15000 mg/L</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<p><strong>Technical Data</strong></p>
<table class="w-fit min-w-(--thread-content-width)" style="height: 119px;" width="440" data-start="59" data-end="158" data-is-last-node="" data-is-only-node="">
<thead data-start="59" data-end="80">
<tr data-start="59" data-end="80">
<th class="last:pe-10" data-start="59" data-end="71" data-col-size="sm">Parameter</th>
<th class="last:pe-10" data-start="71" data-end="80" data-col-size="sm">Value</th>
</tr>
</thead>
<tbody data-start="91" data-end="158" data-is-last-node="">
<tr data-start="91" data-end="111">
<td data-start="91" data-end="104" data-col-size="sm">Auto &#8211; OFF</td>
<td data-col-size="sm" data-start="104" data-end="111">  Yes</td>
</tr>
<tr data-start="112" data-end="138">
<td data-start="112" data-end="126" data-col-size="sm">Portability</td>
<td data-col-size="sm" data-start="126" data-end="138">  Benchtop</td>
</tr>
<tr data-start="139" data-end="158" data-is-last-node="">
<td data-start="139" data-end="152" data-col-size="sm">Compliance</td>
<td data-col-size="sm" data-start="152" data-end="158" data-is-last-node="">  CE</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>Measuring Range</strong></p>
<table class="w-fit min-w-(--thread-content-width)" style="height: 129px;" width="753" data-start="69" data-end="357">
<thead data-start="69" data-end="118">
<tr data-start="69" data-end="118">
<th class="last:pe-10" data-start="69" data-end="81" data-col-size="sm">Test Name</th>
<th class="last:pe-10" data-start="81" data-end="99" data-col-size="sm">Measuring Range</th>
<th class="last:pe-10" data-start="99" data-end="118" data-col-size="sm">Chemical Method</th>
</tr>
</thead>
<tbody data-start="134" data-end="357">
<tr data-start="134" data-end="191">
<td data-start="134" data-end="146" data-col-size="sm">COD HR TT</td>
<td data-col-size="sm" data-start="146" data-end="169">   200 &#8211; 15000 mg/L COD</td>
<td data-col-size="sm" data-start="169" data-end="191">Dichromate / H₂SO₄</td>
</tr>
<tr data-start="192" data-end="247">
<td data-start="192" data-end="205" data-col-size="sm">COD LMR TT</td>
<td data-col-size="sm" data-start="205" data-end="225">   15 &#8211; 300 mg/L COD</td>
<td data-col-size="sm" data-start="225" data-end="247">Dichromate / H₂SO₄</td>
</tr>
<tr data-start="248" data-end="301">
<td data-start="248" data-end="260" data-col-size="sm">COD LR TT</td>
<td data-col-size="sm" data-start="260" data-end="279">   3 &#8211; 150 mg/L COD</td>
<td data-col-size="sm" data-start="279" data-end="301">Dichromate / H₂SO₄</td>
</tr>
<tr data-start="302" data-end="357">
<td data-start="302" data-end="314" data-col-size="sm">COD MR TT</td>
<td data-col-size="sm" data-start="314" data-end="335">   20 &#8211; 1500 mg/L COD</td>
<td data-col-size="sm" data-start="335" data-end="357">Dichromate / H₂SO₄</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/cod-set-up-md-610/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Thermoreactor RD 125</title>
		<link>https://www.vincalabtech.com/product/thermoreactor-rd-125/</link>
					<comments>https://www.vincalabtech.com/product/thermoreactor-rd-125/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Fri, 10 Apr 2026 11:30:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3298</guid>

					<description><![CDATA[Flexible thermoreactor for sample preparation of photometrical determination of COD, total chrome, total phosphate, total nitrogen and TOC. Digestion is possible with three temperature ranges and three pre-programmed reaction times.]]></description>
										<content:encoded><![CDATA[<p><strong>Three Temperature Ranges</strong><br />
The reactor can operate optionally with 100°C, 120°C or 150°C – depending in each case on the sample to be prepared.</p>
<p><strong>Three Different Reaction Times</strong><br />
Three different reaction times are available with 30, 60 and 120 minutes. Your advantage: Afterwards the unit switched itself off automatically.</p>
<p><strong>Large Cuvette Shaft</strong><br />
Place up to 24 16-mm-round cuvettes in the RD 125.</p>
<p><strong>Voltage Change Possible</strong><br />
The RD 125 can be used with various voltages: Choose 110 V and<br />
220 V with the voltage selector on the back.</p>
<p>&nbsp;</p>
<p><strong>Technical Data</strong></p>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Auto-OFF</td>
<td>Yes</td>
</tr>
<tr>
<td>Power Supply</td>
<td>230V / 50–60Hz or 115V / 50–60Hz</td>
</tr>
<tr>
<td>Beeper</td>
<td>Max. 88 dB (Piezo buzzer)</td>
</tr>
<tr>
<td>Suggestion Temperature</td>
<td>100°C / 120°C / 150°C</td>
</tr>
<tr>
<td>Heating-up Rate</td>
<td>20°C → 150°C in 12 minutes</td>
</tr>
<tr>
<td>Selected Time</td>
<td>30 / 60 / 120 minutes and continuous operation</td>
</tr>
<tr>
<td>Environmental Conditions</td>
<td>10–40°C, max. 85% relative humidity</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE</td>
</tr>
<tr>
<td>Dimensions</td>
<td>219 × 171 × 248 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>3.9 kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/thermoreactor-rd-125/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>TB 211 IR Portable Turbidimeter</title>
		<link>https://www.vincalabtech.com/product/turbidimeter-tb-350-copy/</link>
					<comments>https://www.vincalabtech.com/product/turbidimeter-tb-350-copy/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Fri, 10 Apr 2026 11:23:15 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3296</guid>

					<description><![CDATA[A compact instrument for reliable and easy determination of turbidity. A ring memory with 125 data sets and a USB interface guarantee an efficient data management.
<ul>
 	<li>Range 0.01 - 1100 NTU</li>
 	<li>Measurement with infrared light at an angle of 90 °</li>
 	<li>Measurement of colored liquids</li>
 	<li>Easy handling</li>
</ul>
&#160;]]></description>
										<content:encoded><![CDATA[<h3>Technical Data</h3>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Optics</td>
<td>temperaturecompensated LED ( λ = 860 nm) and photosensor amplifier in water proof sample chamber, infrared light</td>
</tr>
<tr>
<td>Measuring Principle</td>
<td>nephelometric (90° scattered light)</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>0,01-1100 NTU (Autorange)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 2.5 % of reading, or ± 0.01 NTU, whichever is bigger, in the range of 0.01 &#8211; 500 NTU ; ± 5 % of reading in the range of 500 &#8211; 1000 NTU</td>
</tr>
<tr>
<td>Display</td>
<td>backlit LCD</td>
</tr>
<tr>
<td>Interfaces</td>
<td>Micro-USB</td>
</tr>
<tr>
<td>Operation</td>
<td>polycarbonate membrane, splash proof</td>
</tr>
<tr>
<td>Internal Storage</td>
<td>internal ring memory for 125 data sets</td>
</tr>
<tr>
<td>Clock</td>
<td>Real Time Clock and Date</td>
</tr>
<tr>
<td>Portability</td>
<td>Portable</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE</td>
</tr>
<tr>
<td>Dimensions</td>
<td>4.33 x 2.17 x 7.48&#8243;</td>
</tr>
<tr>
<td>Weight with Packaging</td>
<td>(Basic Unit)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/turbidimeter-tb-350-copy/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>TB350 IR Portable Turbidimeter</title>
		<link>https://www.vincalabtech.com/product/turbidimeter-tb-350/</link>
					<comments>https://www.vincalabtech.com/product/turbidimeter-tb-350/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Fri, 10 Apr 2026 11:22:25 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3293</guid>

					<description><![CDATA[Ideal for field and environmental testing, the Lovibond TB 350 turbidity meter delivers the most reliable measurements for low range to high range samples without sacrificing accuracy.

A <strong data-start="2" data-end="18">turbidimeter</strong> is an analytical instrument used to measure the turbidity or cloudiness of a liquid caused by suspended particles.<br data-start="133" data-end="136" />It works by detecting how much light is scattered by particles in the sample, helping assess water quality and clarity.]]></description>
										<content:encoded><![CDATA[<ul>
<li>Reads up to 4000 NTU without the need for dilutions</li>
<li>Touchscreen interface for ease of operation</li>
<li>Easily save and recall measurement data sets</li>
<li>ISO 7027 compliant</li>
</ul>
<h3>Technical Data</h3>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Model</td>
<td>Model WM-040-1004 (IR)</td>
</tr>
<tr>
<td>Light Source</td>
<td>IR LED (860 nm)</td>
</tr>
<tr>
<td>Regulatory Compliance</td>
<td>ISO 7027</td>
</tr>
<tr>
<td>Measuring Principle</td>
<td>Nephelometric (Multipath 90° BLAC)</td>
</tr>
<tr>
<td>Measuring Range</td>
<td>0.01 &#8211; 4000 NTU (FNU)</td>
</tr>
<tr>
<td>Accuracy</td>
<td>± 1.8 % of reading + straylight</td>
</tr>
<tr>
<td>Stray Light</td>
<td>&lt; 0.014 NTU</td>
</tr>
<tr>
<td>Display Units</td>
<td>NTU, FNU, Degrees, mg/L Kaolin, mg/L PSL</td>
</tr>
<tr>
<td>Reading Modes</td>
<td>Single, Signal Averaging, Fast-Settling</td>
</tr>
<tr>
<td>Calibration Options</td>
<td>Full-range calibration from 0 &#8211; 4000 NTU</td>
</tr>
<tr>
<td>Detector</td>
<td>Silicon Photodiode</td>
</tr>
<tr>
<td>Sample Required</td>
<td>10 mL (0.4 oz)</td>
</tr>
<tr>
<td>Display</td>
<td>Full-Colour Touchscreen</td>
</tr>
<tr>
<td>Display Size</td>
<td>55 x 95 mm (W x H)</td>
</tr>
<tr>
<td>Interfaces</td>
<td>USB-A USB-C</td>
</tr>
<tr>
<td>Data Logger</td>
<td>250 measurements, all calibrations, verifications and factory-restore actions</td>
</tr>
<tr>
<td>Data Transfer Format</td>
<td>.csv</td>
</tr>
<tr>
<td>Power Supply</td>
<td>4 batteries (AA) 3 NiMH-battery pack (AA) Universal (90 &#8211; 240 VAC), via external power supply</td>
</tr>
<tr>
<td>Compliance</td>
<td>CE CSA FCC A RoHS TÜV UL WEE</td>
</tr>
<tr>
<td>Languages User Interface</td>
<td>German, English, French, Spanish, Portuguese, Chinese, Japanese, Dutch, Turkish, Polish</td>
</tr>
<tr>
<td>Languages Quick Start Guide</td>
<td>German, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian</td>
</tr>
<tr>
<td>Languages Full User Manual</td>
<td>German, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian</td>
</tr>
<tr>
<td>Dimensions</td>
<td>6.1 x 3.27 x 8.86&#8243;</td>
</tr>
<tr>
<td>Weight with Packaging</td>
<td>(898 g with four AA alkaline batteries)</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/turbidimeter-tb-350/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>NIRS DS3 Feed Analyser</title>
		<link>https://www.vincalabtech.com/product/nirs-ds3-feed-analyser/</link>
					<comments>https://www.vincalabtech.com/product/nirs-ds3-feed-analyser/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 10:30:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3180</guid>

					<description><![CDATA[<p class="sub-header">Advanced feed analysis for everyone. The innovative NIRS™ DS3 combines unique analytical performance with the latest software and networking services, making reliable test data for decision-making more available than ever. It’s a complete solution that supports all aspects of your analytical operations from calibration development to measurement and data integration.</p>]]></description>
										<content:encoded><![CDATA[<h3>Technical Specification</h3>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Dimensions (w x d x h)</td>
<td>375 x 490 x 300 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>27 kg</td>
</tr>
<tr>
<td>Degree of protection</td>
<td>IP 65</td>
</tr>
<tr>
<td>Measurement mode</td>
<td>Reflectance or transflectance (for liquids)</td>
</tr>
<tr>
<td>Wavelength range</td>
<td>400 &#8211; 2500 nm</td>
</tr>
<tr>
<td>Detector</td>
<td>Silicon (400 &#8211; 1100 nm), Lead Sulphide, PbS (1100 &#8211; 2500 nm)</td>
</tr>
<tr>
<td>Optical bandwidth</td>
<td>8.75 ± 0.1 nm</td>
</tr>
<tr>
<td>Data resolution</td>
<td>0.5 nm</td>
</tr>
<tr>
<td>Number of data points</td>
<td>4200</td>
</tr>
<tr>
<td>Number of subsamples</td>
<td>Default: 7 for small cup; 8 for large cup</td>
</tr>
<tr>
<td>Self test</td>
<td>12 minutes (variable)</td>
</tr>
<tr>
<td>Analysis time</td>
<td>&lt;1 minute for 32 scans (8 subsamples, 4 scans per subsample)</td>
</tr>
<tr>
<td>Network connections</td>
<td>IQX<img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2122.png" alt="™" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Device Management</td>
</tr>
<tr>
<td>Installation requirements</td>
<td></td>
</tr>
<tr>
<td>Voltage supply</td>
<td>100-240 V AC*, frequency 50-60 Hz, Class 1, protective earth</td>
</tr>
<tr>
<td>Ambient temperature</td>
<td>5 &#8211; 40°C</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>-20 to 70°C</td>
</tr>
<tr>
<td>Ambient humidity</td>
<td>&lt; 93% RH</td>
</tr>
<tr>
<td>Mechanical environment</td>
<td>Stationary during use</td>
</tr>
<tr>
<td>EMC environment</td>
<td>Laboratory use, industry requirements</td>
</tr>
<tr>
<td>*Mains supply voltage fluctuations not exceeding ±10% of the rated voltage.</td>
<td></td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/nirs-ds3-feed-analyser/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Infratech Whole Grain &#038; Flour Analyser</title>
		<link>https://www.vincalabtech.com/product/infratech-whole-grain-flour-analyser/</link>
					<comments>https://www.vincalabtech.com/product/infratech-whole-grain-flour-analyser/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 10:30:20 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3179</guid>

					<description><![CDATA[<p class="sub-header">Solid, straightforward and reliable, Infratec™ draws on the latest advances in NIR technology, connectivity and usability. It makes the job of quality control easier and less time-consuming as a reliable cornerstone for any grain handling operation.</p>]]></description>
										<content:encoded><![CDATA[<h2 class=" blue" style="text-align: center;">Technical specification</h2>
<div class="table__shadow">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td align="left" valign="top"><strong>Feature</strong></td>
<td colspan="2" align="left" valign="top"><strong>Specification</strong></td>
</tr>
<tr>
<td align="left" valign="top">Dimensions (W x D x H)</td>
<td colspan="2" align="left" valign="top">410 x 460 x 415 mm</td>
</tr>
<tr>
<td align="left" valign="top">Weight</td>
<td colspan="2" align="left" valign="top">28.5 kg (31 kg with test weight module)</td>
</tr>
<tr>
<td align="left" valign="top">Voltage</td>
<td colspan="2" align="left" valign="top">220-240V 50-60Hz or 110-120V</td>
</tr>
<tr>
<td align="left" valign="top">Rated current</td>
<td colspan="2" align="left" valign="top">1.0A (110-120V) / 0.5A (220-240V)</td>
</tr>
<tr>
<td align="left" valign="top">Fuse</td>
<td colspan="2" align="left" valign="top">T 5 A (250V)</td>
</tr>
<tr>
<td align="left" valign="top">Power consumption</td>
<td colspan="2" align="left" valign="top">85 W (24V)</td>
</tr>
<tr>
<td align="left" valign="top">Input supply</td>
<td colspan="2" align="left" valign="top">24V DC from FOSS approved power supply</td>
</tr>
<tr>
<td align="left" valign="top">Spectrometer</td>
<td colspan="2" align="left" valign="top">Scanning monochromator</td>
</tr>
<tr>
<td align="left" valign="top">Wavelength range</td>
<td colspan="2" align="left" valign="top">570 &#8211; 1100 nm</td>
</tr>
<tr>
<td align="left" valign="top">Detector</td>
<td colspan="2" align="left" valign="top">Silicon</td>
</tr>
<tr>
<td align="left" valign="top">Optimal bandwidth</td>
<td colspan="2" align="left" valign="top">7 nm</td>
</tr>
<tr>
<td align="left" valign="top">Number of data points/scan</td>
<td colspan="2" align="left" valign="top">1061</td>
</tr>
<tr>
<td align="left" valign="top">Mode</td>
<td colspan="2" align="left" valign="top">Transmittance</td>
</tr>
<tr>
<td align="left" valign="top">Light source</td>
<td colspan="2" align="left" valign="top">Tungsten halogen lamp</td>
</tr>
<tr>
<td align="left" valign="top">Interface</td>
<td colspan="2" align="left" valign="top">Ethernet, 3 x USB (full function) including one on the instrument front for easy access</td>
</tr>
<tr>
<td align="left" valign="top">Display</td>
<td colspan="2" align="left" valign="top">10 inch capacitive touch screen</td>
</tr>
<tr>
<td align="left" valign="top">Noise Level</td>
<td colspan="2" align="left" valign="top">&lt; 70 dB(A)</td>
</tr>
<tr>
<td align="left" valign="top">Degree of protection</td>
<td colspan="2" align="left" valign="top">IP 54</td>
</tr>
<tr>
<td align="left" valign="top"></td>
<td colspan="2" align="left" valign="top"></td>
</tr>
<tr>
<td colspan="3" align="left" valign="top"><strong>Sample handling and result presentation</strong></td>
</tr>
<tr>
<td align="left" valign="top">Analysis time</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Less than 60 seconds for 10 sub-samples including test weight analysis and as little as 40 seconds when dynamic sub-sampling enabled</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Path length</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Variable cell automatically controlled from 6 &#8211; 33 mm</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Result report</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Presented on the display as default. Can be sent to PC/LIMS and the printer port</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Outlier function</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Warnings and options for the presentation of the result</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Software</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Menu driven with touch screen interface</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Regression programs</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">ANN (Artificial Neural Network); PLS (Partial Least Squares)</p>
</td>
</tr>
<tr>
<td align="left" valign="top">No. of sub-samples</td>
<td colspan="2" align="left" valign="top">
<p class="Pa3">Between 1 and 30 sub-samples (10 sub-samples standard)</p>
</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/infratech-whole-grain-flour-analyser/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>NIRS™ DA1650 Oilseed Crush Analyser</title>
		<link>https://www.vincalabtech.com/product/nirs-da1650-oilseed-crush-analyser/</link>
					<comments>https://www.vincalabtech.com/product/nirs-da1650-oilseed-crush-analyser/#respond</comments>
		
		<dc:creator><![CDATA[VincaLabtech]]></dc:creator>
		<pubDate>Wed, 08 Apr 2026 10:29:28 +0000</pubDate>
				<guid isPermaLink="false">https://www.vincalabtech.com/?post_type=product&#038;p=3175</guid>

					<description><![CDATA[<strong>Key features of the NIRS™ DA1650 for Oilseed Crush analyser
</strong>
•<span class="Apple-tab-span"> </span>ISO compliant NIR analysis
•<span class="Apple-tab-span"> </span>Rapid analysis of protein, moisture and oil
•<span class="Apple-tab-span"> </span>Low maintenance
•<span class="Apple-tab-span"> </span>Robust design
•<span class="Apple-tab-span"> </span>Factory standardised
•<span class="Apple-tab-span"> </span>Compatible with other FOSS NIR solutions
•<span class="Apple-tab-span"> </span>Ready to use calibrations for a variety of sample types
•<span class="Apple-tab-span"> </span>Remotely supported through Mosaic network software
•<span class="Apple-tab-span"> </span>Built-in computer with intuitive touchscreen interface]]></description>
										<content:encoded><![CDATA[<h3>Technical Specification</h3>
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td align="left" valign="top"><strong>Feature</strong></td>
<td align="left" valign="top"><strong>Specification</strong></td>
</tr>
<tr>
<td align="left" valign="top">Dimensions (W x D x H)</td>
<td align="left" valign="top">230 x 530 x 280 mm</td>
</tr>
<tr>
<td align="left" valign="top">Weight</td>
<td align="left" valign="top">16 kg</td>
</tr>
<tr>
<td align="left" valign="top">Degree of protection</td>
<td align="left" valign="top">IP 65 (Dust and water proof)</td>
</tr>
<tr>
<td align="left" valign="top">Measurement mode</td>
<td align="left" valign="top">Reflectance</td>
</tr>
<tr>
<td align="left" valign="top">Wavelength range</td>
<td align="left" valign="top">1100 – 1650 nm</td>
</tr>
<tr>
<td align="left" valign="top">Detector</td>
<td align="left" valign="top">Diode array</td>
</tr>
<tr>
<td align="left" valign="top">Analysis time</td>
<td align="left" valign="top">&lt;1 minute*</td>
</tr>
<tr>
<td align="left" valign="top">*Adjustable</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://www.vincalabtech.com/product/nirs-da1650-oilseed-crush-analyser/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>